From b8fe9902f3c6c50ca6a23e24fcea99582beebc65 Mon Sep 17 00:00:00 2001
From: Martin Pitt <martinpitt@gnome.org>
Date: Tue, 22 Oct 2013 10:02:51 +0200
Subject: [PATCH 2/3] linux: Clamp percentage for overfull batteries
Some batteries report energy > energy_full and a percentage ("capacity"
attribute) > 100%. Clamp these within 0 and 100% for both plausibility as well
as to avoid setting an out-of-range property which would then become 0%.
https://launchpad.net/bugs/1240673
---
src/linux/integration-test | 33 +++++++++++++++++++++++++++++++++
src/linux/up-device-supply.c | 4 ++++
2 files changed, 37 insertions(+)
diff --git a/src/linux/integration-test b/src/linux/integration-test
index 8489bf3..4be1922 100755
--- a/src/linux/integration-test
+++ b/src/linux/integration-test
@@ -442,6 +442,39 @@ class Tests(unittest.TestCase):
self.assertEqual(self.get_dbus_property('OnLowBattery'), False)
self.stop_daemon()
+ def test_battery_overfull(self):
+ '''battery which reports a > 100% percentage for a full battery'''
+
+ self.testbed.add_device('power_supply', 'BAT0', None,
+ ['type', 'Battery',
+ 'present', '1',
+ 'status', 'Full',
+ 'current_now', '1000',
+ 'charge_now', '11000000',
+ 'charge_full', '10000000',
+ 'charge_full_design', '11000000',
+ 'capacity', '110',
+ 'voltage_now', '12000000'], [])
+
+ self.start_daemon()
+ devs = self.proxy.EnumerateDevices()
+ self.assertEqual(len(devs), 1)
+ bat0_up = devs[0]
+
+ # should clamp percentage
+ self.assertEqual(self.get_dbus_dev_property(bat0_up, 'Percentage'), 100.0)
+ self.assertEqual(self.get_dbus_dev_property(bat0_up, 'IsPresent'), True)
+ self.assertEqual(self.get_dbus_dev_property(bat0_up, 'State'),
+ UP_DEVICE_STATE_FULLY_CHARGED)
+ self.assertEqual(self.get_dbus_dev_property(bat0_up, 'Energy'), 132.0)
+ # should adjust EnergyFull to reality, not what the battery claims
+ self.assertEqual(self.get_dbus_dev_property(bat0_up, 'EnergyFull'), 132.0)
+ self.assertEqual(self.get_dbus_dev_property(bat0_up, 'EnergyFullDesign'), 132.0)
+ self.assertEqual(self.get_dbus_dev_property(bat0_up, 'Voltage'), 12.0)
+ self.assertEqual(self.get_dbus_dev_property(bat0_up, 'PowerSupply'), True)
+ self.assertEqual(self.get_dbus_dev_property(bat0_up, 'Type'), 2)
+ self.stop_daemon()
+
def test_battery_temperature(self):
'''battery which reports temperature'''
diff --git a/src/linux/up-device-supply.c b/src/linux/up-device-supply.c
index 8020277..b953d65 100644
--- a/src/linux/up-device-supply.c
+++ b/src/linux/up-device-supply.c
@@ -708,6 +708,10 @@ up_device_supply_refresh_battery (UpDeviceSupply *supply)
/* get a precise percentage */
if (sysfs_file_exists (native_path, "capacity")) {
percentage = sysfs_get_double (native_path, "capacity");
+ if (percentage < 0.0f)
+ percentage = 0.0f;
+ if (percentage > 100.0f)
+ percentage = 100.0f;
/* for devices which provide capacity, but not {energy,charge}_now */
if (energy < 0.1f && energy_full > 0.0f)
energy = energy_full * percentage / 100;
--
2.6.4
|